Home » How To: Use an Open Collector Output

How To: Use an Open Collector Output

All new Gill level sensors come with a secondary output function which operates as a high or low level switch. So what is it and how do I use an Open Collector switch output?

Essentially the level sensor has an on board electronic switch (a Metal–Oxide–Semiconductor Field-Effect Transistor or MOSFET, if you are interested) that can be set-up to open or close at given liquid level conditions. Its exact switch point can be configured by the GS Level configuration tool available for download from their website www.gillsc.com/support

When combined with other components, the Open Collector Output can drive an LED to indicate reserve fuel level, a relay to switch on a pump or an Opto-Isolator to drive any number of other devices.

How do I choose the right value for ‘R’? 

Resistor Value – R

R = (Vindicator- VLED) / ILED

VLED = Voltage drop across LED (Volts)

ILED = Current flowing through LED (Amps)

Vindicator = Supply Voltage (Volts)

Resistor Power Rating 

W = (Vindicator – VLED)² / R

Ready to learn more about how to best use your new sensors? Fill out the form below, we would be happy to help.

"*" indicates required fields

This field is hidden when viewing the form
This field is for validation purposes and should be left unchanged.

Related Topics

Everight Position provides solutions tailored for hazardous environments. With our focus on customer well-being and reliability, we’re committed to equipping
Over the past 15 years Everight Position has worked with a lot of unique sensors. But one of our favorites
In the world of industrial machinery and high-tech equipment, maintaining optimal lubrication is not just a matter of efficiency—it’s a
Recently, obtaining the Inductosyn and components for maintenance has become more difficult. For decades the Inductosyn from Farrand Controls /