Part no.: X132
• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
• Sensor Mounting: 1/2" UNF ThreadSpring loaded plunger
• Available in any measurement range up to 100mm
• Sealed to IP67
The intrinsically safe X132 is ATEX and IECEx approved for use in potentially explosive gas/vapour atmospheres. It is designed for gauge head positioning in industrial and scientific applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The X132, like all Positek sensors, provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-50mm and with full EMC protection built in.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is very robust, the body and plunger being made of stainless steel for long service life and environmental resistance.
The plunger is spring loaded with a domed end. The X112 is easy to install with a long ½ inch UNF mounting thread and is supplied with two lock nuts for positioning. Environmental sealing is to IP67.
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
"*" indicates required fields
Positek
Positek
Positek
Positek
Submersible Linear Sensors: High-Accuracy Solutions for Harsh Environments Introduction to Submersible Linear Sensors Positek’s portfolio includes a range of high-accuracy linear sensors specifically designed for use in submersible applications. Made from marine-grade stainless steel and offering reliability beyond what is possible from a submersible LVDT or linear potentiometer, our sensors have served various industries, including […]
Rotary encoders are used in a variety of applications to provide feedback on position, speed, direction, or angle. There are several different encoder types…
Understanding Hazardous Environments and Their Risks
Hazardous environments are prevalent across various industries, presenting significant risks due to the presence of explosive materials, dangerous gasses, or other hazardous conditions.
Technical Note: Intrinsically Safe vs. Inherently Safe Sensors
Intrinsically safe (IS) sensors are designed to operate safely in hazardous areas where there is a risk of explosion. IS sensors limit the amount of electrical and thermal energy that can be released in the event of a fault, to a level below that which is capable of igniting flammable gases, vapors, or dust.