Positek

H118

Part no.: H118

Key Features

• CSA approved to: Class I, Zone 0

• Sensor Mounting: Flange or body clampsSpring loaded pushrod option available

• Available in any measurement range from 0-2mm to 0-50mm(for 51-100mm range see P138)

• Sealed to IP67

The intrinsically safe H118 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres. The H118 is designed for a wide range of industrial applications and is ideal for OEMs seeking good sensor performance in situations where a short-bodied sensor is required for operation in hazardous areas. The unit is compact and space-efficient, being responsive along almost its entire length, and like all Positek® sensors provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-2mm to 0-50mm and with full EMC protection built in. Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor has a rugged stainless steel body and plunger. It is easy to install and set up, mounting options include flange and body clamps. The plunger can be supplied free or captive, with female M4 thread, or spring-loaded with a ball end. The H118 also offers a wide range of mechanical options, environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

X106

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: In-cylinder
  • Available in any measurement range from 0-5mm to 0-800mm
  • Sealed to IP65/67 depending on connector/cable option

Positek

G130

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: In-cylinder
  • Available in any measurement range from 0-400mm to 0-1485mm
  • Sealed to IP65/67 depending on connector/cable option

Positek

M133

  • ATEX/IECEx approved for mining
  • Sensor Mounting: Flange or body clampsSpring loaded pushrod option available
  • Available in any measurement range from 0-51mm to 0-100mm(for 2-50mm range see P103)
  • Sealed to IP65/67 depending on connector/cable option

Positek

P118

  • Body Diameter: 19mm
  • Sensor Mounting: Flange or body clampsSpring loaded pushrod option available
  • Available in any measurement range from 0-2mm to 0-50mm(for 51-100mm range see P138)
  • Sealed to IP67
Blog:

Spine Surgery Robot

Spinal surgery robot with advanced robotic guided technologies supports high requirements of predictable surgical procedures.

Inductosyn: End of an Era, New Opportunities or Both?

Recently, obtaining the Inductosyn and components for maintenance has become more difficult. For decades the Inductosyn from Farrand Controls / Ruhle Companies sat near the top of the rotary sensor hierarchy. Providing sub 2 arcsec (0.5 mdeg) accuracies, it combined the robustness of a resolver with the performance of the best optical encoders. Despite its shortcomings, it found plenty of customers, from airborne infrared and radar systems, to telescopes, satellite communication antennae (SATCOM), machine tooling and low-pressure vacuum chambers.

Exploring Inclinometers with Digital Interfaces: CANopen, J1939, Modbus RTU, and SSI

While they may be small, the role of rotary encoders in spacecraft is vital, demanding a balance between performance, reliability, and the unforgiving environment of space. From NASA’s Robonaut II to automated material handling systems on the International Space Station, Everight has worked with engineers to put rotary encoders into ‘the final frontier.’

Introduction to Intrinsically Safe Sensors

Intrinsically safe (IS) sensors are unable to produce a spark strong enough to cause ignition. Learn how this is accomplished and design considerations when using IS sensors.

Download Now

This field is for validation purposes and should be left unchanged.