Positek

E114

Part no.: E114

Key Features

• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)

• Sensor Mounting: M5 rod eyes, body clamps or M5 threadsSpring loaded pushrod option available

• Available in any measurement angle from 0-5mm to 0-800mm

• Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)

The intrinsically safe 10 bar E114 is an ATEX and IECEx approved affordable, durable, high-accuracy position sensor.

The E114, like all Positek sensors, provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in. The sensor is very robust, the body and push rod being made of stainless steel for long service life and environmental resistance. Derived from the popular E101, the E114 has been designed for applications where the sensor may be completely submerged in water up to a pressure of 10Bar, but good sensor performance and cost are still important.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at 856-727-9500

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

H115

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: M8 rod eyes, body clamps or M8 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800m
  • Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)

Positek

Positek X500

  • ATEX/IECE: Ex II 1G; Ex ia IIC T4 GA
  • 0.5-9.5V or 4-20mA outputs
  • ATEX variants of P502, P505 and P520 available
  • Up to 160 deg range

Positek

E101

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 Rod Eyes, Body Clamps or M5 ThreadsSpring loaded pushrod option available
  • Any stroke from 0-5mm to 0-800mm (e.g. 305mm)
  • Sealed to IP65/67 depending on connector/cable option

Positek

X125

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M8 rod eyes, body clamps or M8 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800mm
  • Sealed to IP68 350bar, 3500msw, 5000psi
Blog:

Fiber Optics Encoders

Read how Micronor’s fiber optic encoders provide an inherently safe sensing option with immunity to lightning, radiation and magnetic fields.

Submersible Linear Sensors

Submersible Linear Sensors: High-Accuracy Solutions for Harsh Environments Introduction to Submersible Linear Sensors Positek’s portfolio includes a range of high-accuracy linear sensors specifically designed for use in submersible applications. Made from marine-grade stainless steel and offering reliability beyond what is possible from a submersible LVDT or linear potentiometer, our sensors have served various industries, including […]

Potentiometers That Make Sense for Sensing

Despite their perceived simplicity, potentiometers can still be an appropriate option in today’s ever-complicated automation industry. Fundamentally a variable resistor, modern potentiometers also offer more traditional outputs such as voltage and current which are common to more expensive sensors.

How Getting Older is Changing Robotics

While it may be noble to develop robotics to help older demographics in society, companies small and large alike have good business reasons to do so.   Roughly 10,000 Baby Boomers retire daily. These consumers not only have wants and needs but have worked their whole lives to create a nest egg to fund them. […]

Download Now

This field is for validation purposes and should be left unchanged.