Part no.: X120
• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
• Sensor Mounting: M18 or 3/4" UNF threadTarget tube flanges available
• Available in any measurement angle from 0-5mm to 0-800mm
• Sealed to IP68 350bar, 3500msw, 5000psi(combined hydraulic and water pressure)
The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.
Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.
The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.
This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.
The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.
Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.
The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.
This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.
The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.
Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.
The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.
Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.
This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.
"*" indicates required fields
Positek
Positek
Positek
Positek
Seeing Is Believing: POSITAL 3D drawings now available for millions of encoders
POSITAL’s product finder has generated full specification custom datasheets for years. Rather than having to guess on specifications from a confusing product configurator, POSITAL provides part specific datasheets in real time for the given part number of interest.
Improved Encoder Accuracy Brings Hidden Benefits
Capacitive rotary encoders such as those from Netzer Precision are known for their low profile, high noise immunity and excellent accuracy. As a result, they are an excellent choice for applications such as camera systems, radar, slip-rings and robotic joints. Often times in these tasks the encoder is used for velocity feedback, ensuring a smooth […]
Everight Position Receives Top Certification from POSITAL
Everight Position is excited to announce that our application engineer, Jarrod Orszulak has been named a Certified Product Specialist and a Certified Sales Engineer by POSITAL for their rotary encoders, linear and tilt sensors.
Inductosyn vs Modern Rotary Encoders
An Inductosyn is type of inductive position sensing device from Farrand Controls/ Ruhle Companies. Inductosyns work using the same basic physics as a transformer using planner arrays of inductive windings.