Positek

X120

Part no.: X120

Key Features

• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)

• Sensor Mounting: M18 or 3/4" UNF threadTarget tube flanges available

• Available in any measurement angle from 0-5mm to 0-800mm

• Sealed to IP68 350bar, 3500msw, 5000psi(combined hydraulic and water pressure)

The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.

Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.

The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.

This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.
The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.

Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.

The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.

This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.

The 350bar X120 is an ATEX and IECEx approved version of the S120 cylinder sensor. The X120 is sealed for a maximum of 350bar combined hydraulic and water pressure. The unit is compact, space-efficient and responsive along almost its entire length.

Like all Positek sensors, the X120 provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, our standard range covers any measurement range from 0-5mm to 0-800mm. As with all of our packaged sensors full EMC protection is built in.

The sensor is very robust, the body and target tube are made of 316 stainless steel for long service life and environmental resistance.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with M18 or 3/4″” UNF mounting thread options. The target tube can be supplied plain or with a variety of flanges.

This sensor is waterproof for submersion to 3500 meters (350bar combined water and hydraulic pressure).

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.

Call us for more info at

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

E101

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 Rod Eyes, Body Clamps or M5 ThreadsSpring loaded pushrod option available
  • Any stroke from 0-5mm to 0-800mm (e.g. 305mm)
  • Sealed to IP65/67 depending on connector/cable option

Positek

X101

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 Rod Eyes, Body Clamps or M5 ThreadsSpring loaded pushrod option available
  • Any stroke from 0-5mm to 0-800mm (e.g. 305mm)
  • Sealed to IP65/67 depending on connector/cable option

Positek

E130

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: In-cylinder
  • Available in any measurement range from 0-400mm to 0-1485mm
  • Sealed to IP65/67 depending on connector/cable option

Positek

X117

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 Rod Eyes, Body Clamps or M5 ThreadsSpring loaded pushrod option available
  • Available in any measurement range from 0-5mm to 0-350mm
  • Sealed to IP67
Blog:

TECHNOLOGY LINEAR SENSORS

Many applications require linear motion to be monitored for system control or to ensure safety. With lengths ranging from 1 m to 30m (3’ to 98’), LINARIX linear sensors are available in many configurations to meet an application’s requirements. Options include a wide variety of outputs (including analog, fieldbus and Ethernet variants), heavy duty housings and compact design.

Technical Note: Intrinsically Safe vs. Inherently Safe Sensors

Intrinsically safe (IS) sensors are designed to operate safely in hazardous areas where there is a risk of explosion. IS sensors limit the amount of electrical and thermal energy that can be released in the event of a fault, to a level below that which is capable of igniting flammable gases, vapors, or dust.

Case Study: Retrofitting Water Valves for Remote Position Information

While they may be small, the role of rotary encoders in spacecraft is vital, demanding a balance between performance, reliability, and the unforgiving environment of space. From NASA’s Robonaut II to automated material handling systems on the International Space Station, Everight has worked with engineers to put rotary encoders into ‘the final frontier.’

Rotary Encoder Glossary

This glossary defines common terms used when working with rotary encoders.

Download Now

This field is for validation purposes and should be left unchanged.