Positek

E101

Part no.: E101

Key Features

• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)

• Sensor Mounting: M5 Rod Eyes, Body Clamps or M5 ThreadsSpring loaded pushrod option available

• Any stroke from 0-5mm to 0-800mm (e.g. 305mm)

• Sealed to IP65/67 depending on connector/cable option

The intrinsically safe E101 is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for industrial and scientific feedback applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The unit is highly compact and space-efficient, being responsive along almost its entire length.

The E101, like all Positek sensors, provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in. The sensor is very robust, the body and push rod being made of stainless steel for long service life and environmental resistance.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is easy to install with mounting options including M5 rod eye bearings and body clamps. The push rod can be supplied free or captive, with female M5 thread, an M5 rod eye, or dome end, Captive push rods can be sprung loaded, in either direction, on sensors up to 300mm of travel. Environmental sealing is to IP65 or IP67, depending on selected cable or connector options.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at 856-727-9500

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

G112

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: 1/2" UNF ThreadSpring loaded plunger
  • Available in any measurement range from 0-5mm to 0-50mm
  • Sealed to IP67

Positek

P106

  • Probe Head Diameter: 20mmElectronics Module: 35mm
  • Sensor Mounting: In-cylinder
  • Available in any measurement range from 0-5mm to 0-800mm
  • Sealed to IP65/67 depending on connector/cable option

Positek

H118

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: Flange or body clampsSpring loaded pushrod option available
  • Available in any measurement range from 0-2mm to 0-50mm(for 51-100mm range see P138)
  • Sealed to IP67

Positek

E114

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 rod eyes, body clamps or M5 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800mm
  • Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)
Blog:

Seeing Is Believing: POSITAL 3D drawings now available for millions of encoders

POSITAL’s product finder has generated full specification custom datasheets for years. Rather than having to guess on specifications from a confusing product configurator, POSITAL provides part specific datasheets in real time for the given part number of interest.

Introduction to Intrinsically Safe Sensors

Intrinsically safe (IS) sensors are unable to produce a spark strong enough to cause ignition. Learn how this is accomplished and design considerations when using IS sensors.

How-to: 2 Point Operation of an Open Collector Switch Output

In this example, the switch point has been set to ‘Full Alarm’. By setting the switch point to 90% with an 80% hysteresis, the switch will come on at 90% and switch off at 10%.

Fiber Optics Encoders

Read how Micronor’s fiber optic encoders provide an inherently safe sensing option with immunity to lightning, radiation and magnetic fields.