Positek

E112

Part no.: E112

Key Features

• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)

• Sensor Mounting: 1/2" UNF ThreadSpring loaded plunger

• Available in any measurement range from 0-5mm to 0-50mm

• Sealed to IP67

The intrinsically safe E112 is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for gauge head positioning in industrial and scientific applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The E112, like all Positek sensors, provides a linear output proportional to displacement. Each sensor is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-50mm and with full EMC protection built in.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The sensor is very robust, the body and plunger being made of stainless steel for long service life and environmental resistance.

The plunger is spring loaded with a domed end. The E112 is easy to install with a long ½ inch UNF mounting thread and is supplied with two lock nuts for positioning. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

X132

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: 1/2" UNF ThreadSpring loaded plunger
  • Available in any measurement range up to 100mm
  • Sealed to IP67

Positek

S114

  • Body Diameter: 35mm
  • Sensor Mounting: M5 rod eyes, body clamps or M5 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800mm
  • Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)

Positek

X100

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: In-Cylinder Mounting
  • Any stroke from 0-5mm to 0-800mm (e.g. 305mm)
  • IP65 (connector) / IP67 (cable)

Positek

H133

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: Flange or body clampsSpring loaded pushrod option available
  • Available in any measurement range from 0-51mm to 0-100mm(for 2-50mm range see P103)
  • Sealed to IP65/67 depending on connector/cable option
Blog:

Facing the Inevitable: Sensor Obsolescence, Mitigation Strategies, and Alternatives

Obsolescence. If its only difficulty was remembering how it is spelled it wouldn’t be so bad. And whether you’re trying to replace a sensor that has failed with age or are a manufacturer who can no longer source an important sensor, obsolescence of an inexpensive sensor can create extremely expensive headache. At Everight Position we help customers to understand the causes of sensor obsolescence, explore mitigation strategies and find alternative solutions.

Academic Project

The University of Rochester Baja SAE Team using Opkon potentiometers donated by Everight Position to measure steering angle and suspension height. If your academic project looks like this: Awesome idea Enthusiastic classmates Cases of Red Bull and Mountain Dew Extremely limited financial budget Everight Position wants to help. We are actively looking for University Clubs […]

Intrinsically Safe Absolute Rotary Encoders

In the most hazardous environments, where an explosive atmosphere consisting of flammable gas or vapor is regularly present and a sensor fault cannot be risked, Intrinsically Safe (IS) sensors may be the best sensing option. Generally, these sensors are paired with a barrier which limits the amount of electrical and thermal energy that can enter the Hazardous Area to an amount that is so small that even in the situation of a sensor fault, there is not enough energy to cause an ignition.

Understanding Hazardous Location Classifications

Properly understanding hazardous location classifications is vital for ensuring safety in dangerous environments. This blog provides a comprehensive guide to these classifications and their importance.

Download Now

This field is for validation purposes and should be left unchanged.