Positek

G133

Part no.: G133

Key Features

• CSA approved to: Class I, Zone 0

• Sensor Mounting: Flange or body clampsSpring loaded pushrod option available

• Available in any measurement range from 0-51mm to 0-100mm(for 2-50mm range see P103)

• Sealed to IP65/67 depending on connector/cable option

The intrinsically safe G133 is CSA approved for use in potentially explosive gas/vapour atmospheres. It is designed for a wide range of industrial applications and is ideal for OEMs seeking good sensor performance in situations where a mid-bodied sensor is required for operation in hazardous areas. The unit is compact and space-efficient, being responsive along almost its entire length, and like all Positek sensors provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-51mm to 0-100mm and with full EMC protection built in.

Overall performance, repeatability and stability are outstanding over a wide temperature range.

The sensor has a rugged stainless steel body and plunger. It is easy to install and set up, mounting options include flange and body clamps. The plunger can be supplied free or captive, with female M4 thread, or spring-loaded with a ball end. The G133 also offers a wide range of mechanical options, environmental sealing is to IP65 or IP67 depending on selected cable or connector options.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

G114

  • CSA approved to: Class I, Zone 0
  • Sensor Mounting: M5 rod eyes, body clamps or M5 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800mm
  • Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)

Positek

M133

  • ATEX/IECEx approved for mining
  • Sensor Mounting: Flange or body clampsSpring loaded pushrod option available
  • Available in any measurement range from 0-51mm to 0-100mm(for 2-50mm range see P103)
  • Sealed to IP65/67 depending on connector/cable option

Positek

X114

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: M5 rod eyes, body clamps or M5 threadsSpring loaded pushrod option available
  • Available in any measurement angle from 0-5mm to 0-800mm
  • Sealed to IP68 10bar, 100msw, 145psi(for 350bar sealing see S125)

Positek

E103

  • ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)
  • Sensor Mounting: Flange or Body ClampsSpring loaded pushrod option available
  • Available in any measurement range from  0-2mm to 0-50mm (for 51-100mm range see P133)
  • Sealed to IP65/67 depending on connector/cable option
Blog:

Analog Sensors – Now monitored (easily) in the Cloud

The Trumeter IoT Gateway is a device that allows you to connect your analog sensors to the internet for remote monitoring and data collection through the Trumeter Cloud platform. It is a plug-and-play device that supports up to four analog inputs and includes free access to the Trumeter Cloud dashboard.

Sensors As Tough as You Are

If your environment is dirty, hot, wet, or corrosive your requirements may have some similarities with that of the construction industry.

Understanding Hazardous Location Classifications

Properly understanding hazardous location classifications is vital for ensuring safety in dangerous environments. This blog provides a comprehensive guide to these classifications and their importance.

Redundant Encoder Options

In the world of rotary encoders, modern non-contact sensing technologies and high MTBF (Mean Time Between Failures) specifications are standard. However, in critical applications, redundant sensors are still a necessity. When selecting a solution, several criteria need to be considered, and fortunately, various options are available to simplify the task. Understanding Redundancy in Encoders The […]

Download Now

This field is for validation purposes and should be left unchanged.