Positek

E130

Part no.: E130

Key Features

• ATEX/IECEx approved to: Ex II 1G : Ex ia IIC T4 GA (Ta = -40°C to +80°C)

• Sensor Mounting: In-cylinder

• Available in any measurement range from 0-400mm to 0-1485mm

• Sealed to IP65/67 depending on connector/cable option

The intrinsically safe E130 is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for demanding hydraulic or pneumatic cylinder position feedback applications where service life, environmental resistance and cost are important and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeat-ability and stability are outstanding over a wide temperature range. The unit is highly compact and space-efficient, being responsive along almost its entire length. Like all Positek sensors, the E130 provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-400mm to 0-1485mm and with full EMC protection built in.

The sensor is very rugged, being made of stainless steel with an inert fluoropolymer-sheathed probe and stainless steel target tube. The sensor is easy to install in cylinders and has a wide range of mechanical options. Environmental sealing is to IP65 or IP67 depending on selected cable or connector options.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Call us for more info at 856-727-9500

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.
You may also be interested in:

Positek

P111

  • Body Diameter: 35mm
  • Sensor Mounting: M8 Rod Eyes, Body Clamps or M8 ThreadsSpring loaded pushrod option available
  • Available in any measurement range from 0-5mm to 0-800mm
  • Sealed to IP65/67 depending on connector/cable option

Positek

M112

  • ATEX/IECEx approved for mining
  • Sensor Mounting: 1/2" UNF ThreadSpring loaded plunger
  • Available in any measurement range from 0-5mm to 0-50mm
  • Sealed to IP67

Positek

G005

  •  Provides isolation between the amplifier power supply, the hazardous area and the G005 output signal
  • Input power supply range of 12 to 30 volts DC
  • Factory configured to either 0.5 to 9.5V or 4-20mA
  •  Bandwidth of 4.7kHz, making it ideal for servo control loops.

Positek

Positek P505

  • 19mm diameter body
  • Analog voltage and current outputs
  • 0.25% linearity
  • Measure up to 160 deg range
Blog:

Technical Note: Intrinsically Safe vs. Inherently Safe Sensors

Intrinsically safe (IS) sensors are designed to operate safely in hazardous areas where there is a risk of explosion. IS sensors limit the amount of electrical and thermal energy that can be released in the event of a fault, to a level below that which is capable of igniting flammable gases, vapors, or dust.

Trumeter Process Meter

There is a lot of talk about ‘data’ these days. But what can be just important as the data is how you communicate it.

NASA- Robonaut 2

Robonaut 2 (R2) is a state-of-the-art, highly dexterous anthropomorphic robot. The robot is designed to work with humans and has the ability to use the same workspace and tools.

The robot joints incorporate dual encoders for position and torque feedback while performing in a dynamic application, vibration, shocks, and wide temperature range.

How-to: 2 Point Operation of an Open Collector Switch Output

In this example, the switch point has been set to ‘Full Alarm’. By setting the switch point to 90% with an 80% hysteresis, the switch will come on at 90% and switch off at 10%.