SSI hardware is fairly simple. Just use any RS-422 transceiver to generate the differential signals from/to the microcontroller port pins. Keep reading to learn about the different implementations of SSI hardware. 

Simple SSI Master Implementation

The following example uses the MAX1486 transceiver from MAXIM. RS-422 transceivers are available from many companies, in various shapes and flavours (3.3V; 5V, single transceiver, multiple transceivers in a single chip etc).

SSI Interface with Opto-coupler (Galvanic Insulated)

A different implementation uses a galvanic insulated master. This insulation isolates functional sections of the system. It is an effective method of breaking ground loops by preventing unwanted current from travelling between two units sharing a ground conductor.

The above implementation in figure 2.2 uses an opto-coupler together with a Schmitt-trigger buffer for the receiver stage and an RS-422 level translator for the transmitter. This version uses a 3.3 V supply instead of 5 V. The encoder contains a similar RS-422 transceiver stage. On the encoder side, CLK+ and CLK- are inputs, and DTA+ and DTA- are outputs.

Illustration of SSI Transfers using differential signals

Figure 2.3, shows DTA and CLK at the microcontroller (Ch #1 and Ch #2) and the differential signals to the decoder (D1, D2) and from the encoder (D3, D4).

Illustration of SSI Transfers using differential signals Figure 2.3, shows DTA and CLK at the microcontroller (Ch #1 and Ch #2) and the differential signals to the decoder (D1, D2) and from the encoder (D3, D4).

The clock signal from the SSI master is present as usual, but both input lines (D2 and D3) are low. Since this means the LED inside the opto-coupler is not driven, the pull-up resistor at the output of the optocoupler will return a high signal to the microcontroller (Channel #2).

Interested in discussing the implementation of the SSI interface with us further? Contact us today using the form below!

"*" indicates required fields

This field is hidden when viewing the form
This field is for validation purposes and should be left unchanged.

Related Topics

Intrinsically safe (IS) sensors are designed to operate safely in hazardous areas where there is a risk of explosion. IS
Spacecraft launches present a uniquely demanding environment for sensors. The extreme conditions encountered during liftoff require sensors with exceptional ruggedness,
Recently, obtaining the Inductosyn and components for maintenance has become more difficult. For decades the Inductosyn from Farrand Controls /
Synchronous Serial Interface (SSI) is a widely used serial interface standard for industrial applications especially, rotary encoders. It is a

"*" indicates required fields

Hi, My name is

and I’m interested in the

You can reach me by email at

or phone at

Message

This field is for validation purposes and should be left unchanged.