Part no.: H103
• CSA approved to: Class I, Zone 0
• Sensor Mounting: Flange or Body ClampsSpring loaded pushrod option available
• Available in any measurement range from 0-2mm to 0-50mm (for 51-100mm range see P133)
• Sealed to IP65/67 depending on connector/cable option
The intrinsically safe H103 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for a wide range of industrial applications and is ideal for OEMs seeking good sensor performance in situations where a short-bodied sensor is required for operation in hazardous areas. The unit is compact and space-efficient, being responsive along almost its entire length, and like all Positek sensors provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-2mm to 0-50mm and with full EMC protection built in.
Overall performance, repeatability and stability are outstanding over a wide temperature range.
The sensor has a rugged stainless steel body and plunger. It is easy to install and set up, mounting options include flange and body clamps. The plunger can be supplied free or captive, with female M4 thread, or spring-loaded with a ball end. The H103 also offers a wide range of mechanical options, environmental sealing is to IP65 or IP67 depending on selected cable or connector options.
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier . Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Positek
Positek
Positek
Positek
Spinal surgery robot with advanced robotic guided technologies supports high requirements of predictable surgical procedures.
Robust IncOders that Are Right for Your Application
Zettlex IncOders are non-contact devices for precision angle measurement. They work like a transformer, using an inductive technique. IncOders may be considered as an inductive angle encoder. IncOders are ideally suited to harsh environments – where potentiometers, optical or capacitive devices may prove unreliable.
How-to: 2 Point Operation of an Open Collector Switch Output
In this example, the switch point has been set to ‘Full Alarm’. By setting the switch point to 90% with an 80% hysteresis, the switch will come on at 90% and switch off at 10%.